Maxsys and MX Series Software Administrator’s Guide 275
Auto Levels - ConCAD identifies the lightest and darkest
pixels and then redistributes intermediate pixel values
proportionately to provide a more balanced image.
The recommended settings are:
Black Limit - 1
White Limit - 230
Black Clip - 0.5%
White Clip - 0.5%
The use of Auto Level is preferable to changing the
input levels.
Unsharp Mask - Used to sharpen the image. The image
must be resized before using this filter. The
recommended settings (for a 400 DPI image) are:
Radius - 35
Amount - 270
Threshold - 90
If a different DPI is used for printing, a different radius is
needed to obtain the same results. Generally, a radius
of 3.5 works well for 400 DPI +/- 10%.