Maxsys and MX Series Software Administrator’s Guide 107
Z-Order Sets the front to back order of elements on the Z axis. Zero (0)
represents the farthest “back” an image can be. For example
if you want Barcode Element B to overlap Barcode Element
A, then Barcode Element A’s Z-Order value would be 0 and
Barcode Element B’s value would be 1.
Justification Changes the value of the Barcode’s baseline as defined by
the X/Y coordinates (Bottom Left, Bottom Center, Bottom
Right). Note that the virtual card does not reflect the change.
Click the icon to select Data Field, Feedback Field, or
Runtime Composite information for this operation.
Barcode Type The Barcode type. Enter the Value, click the icon to use Data
Field information or select from the Barcode Setups directory.
Refer to “Barcode Setup” on page 157 for more information.
Barcode Data The Barcode data to be used in the operation. Enter the
value in the text box or click the icon to select Data Field,
Feedback Field, or Runtime Composite information for this
operation
Print Technology The technology type (Monochrome Mass Transfer, Retransfer)
Graphics Ribbon/
Ribbon Set
(Retransfer)
The ribbon stock to be used in the operation. Enter the value
in the text box or click the icon to use Data Field, Feedback
Field, or Runtime Composite information to select the ribbon
stock. When the Retransfer Print Technology is selected, this
property changes to Ribbon set.
Print Process The process used in the printing operation. This selection
should correspond to the selected Ribbon Set. When
Retransfer Print Technology is selected, along with a ribbon
set and print process, the Settings button will be enabled.
The settings for Spot color print process are: dots-per-inch
(600/1200), Y offset, and grayscale enabled. The setting for
CMY and CMYK setting is Use Color Table.
Advanced Tab Properties
Rotation The value (in degrees) counterclockwise that the Barcode
should rotate. Click the icon to select Data Field, Feedback
Field, or Runtime Composite information for this operation.
Orientation The value (in degrees) counterclockwise that the Barcode is
oriented. Enter the value in the text box or click the icon to
use Data Field, Feedback Field, or Runtime Composite
information for this operation.
Foreground/
Background Color
Click Choose Color to open the color picker with which you
can select the foreground/background color(s).